Chemical Dosing Pump Calculator
Dosing-pump flow to hit a target ppm in a process stream from stock-solution strength.
Size the metering pump so the duty lands at 30โ70% stroke โ full-stroke running leaves no headroom and tiny strokes lose accuracy.
Formula
Chemical Dosing Pump Calculator is a free dosing pump calculation for pump engineers, plumbers and plant designers โ instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.
About Chemical Dosing Pump Calculator
Dosing-pump flow to hit a target ppm in a process stream from stock-solution strength. The calculation implements Q_dose(L/h) = Q(mยณ/h) ร dose(g/mยณ) / C_stock(g/L) (AWWA โ water treatment chemical feed practice). Size the metering pump so the duty lands at 30โ70% stroke โ full-stroke running leaves no headroom and tiny strokes lose accuracy.
How to use Chemical Dosing Pump Calculator
- 1Enter Process water flow in mยณ/h.
- 2Enter Target dose in ppm (mg/L).
- 3Enter Stock solution strength in % w/v (10% = 100 g/L).
- 4Read Dosing rate, Solution per day instantly โ no submit button needed.
- 5Need US units? Flip the SI/Imperial toggle and every field converts.
Why use Chemical Dosing Pump Calculator?
- โImplements the standard formula โ Q_dose(L/h) = Q(mยณ/h) ร dose(g/mยณ) / C_stock(g/L)
- โReference cited on-page: AWWA โ water treatment chemical feed practice
- โOne-click SI โ Imperial toggle โ values convert in place, physics stays in SI
- โLive worked example: the substitution recomputes from your numbers
- โRuns entirely in your browser โ nothing uploaded, free forever
Frequently asked questions
What formula does the Chemical Dosing Pump Calculator use?+
It computes Q_dose(L/h) = Q(mยณ/h) ร dose(g/mยณ) / C_stock(g/L), per AWWA โ water treatment chemical feed practice. The formula is displayed under the result along with a worked example substituted with your own inputs.
What should I keep in mind when using this calculator?+
Size the metering pump so the duty lands at 30โ70% stroke โ full-stroke running leaves no headroom and tiny strokes lose accuracy.
Can I use this for pump selection?+
Use it to establish the duty (flow, head, NPSH, power) and then pick a pump whose curve passes through that point near best efficiency. The tool gives you the engineering numbers a supplier will ask for.
Is the Chemical Dosing Pump Calculator free to use?+
Yes โ completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.
Related Engineering tools
Reynolds Number Calculator
Compute Re from density, velocity, pipe diameter and viscosity โ with instant laminar/turbulent classification.
โ LiveLaminar vs Turbulent Flow Classifier
Classify hydraulic-oil or process-fluid flow regime from kinematic viscosity, line velocity and tube bore.
โ LiveBernoulli Equation Solver
Solve downstream pressure between two points from velocities, elevations and fluid density (ideal, lossless).
โ Live