ToolJoltTools

Dosing Pump Stroke Setting Calculator

Stroke % to set on a metering pump for a target dose rate.

0
Stroke setting (%)

Diaphragm metering pumps stay linear mid-range but drift at the extremes. Calibrate with a draw-down cylinder โ€” nameplate capacity assumes rated back-pressure.

Formula

stroke % = Q_required / Q_max ร— 100
References: API 675 โ€” controlled volume pumps

Dosing Pump Stroke Setting Calculator is a free dosing pump stroke for pump engineers, plumbers and plant designers โ€” instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Dosing Pump Stroke Setting Calculator

Stroke % to set on a metering pump for a target dose rate. The calculation implements stroke % = Q_required / Q_max ร— 100 (API 675 โ€” controlled volume pumps). Diaphragm metering pumps stay linear mid-range but drift at the extremes. Calibrate with a draw-down cylinder โ€” nameplate capacity assumes rated back-pressure.

How to use Dosing Pump Stroke Setting Calculator

  1. 1Enter Pump max capacity (100%) in L/h.
  2. 2Enter Required dose rate in L/h.
  3. 3Read Stroke setting instantly โ€” no submit button needed.
  4. 4Need US units? Flip the SI/Imperial toggle and every field converts.

Why use Dosing Pump Stroke Setting Calculator?

  • โœ“Implements the standard formula โ€” stroke % = Q_required / Q_max ร— 100
  • โœ“Reference cited on-page: API 675 โ€” controlled volume pumps
  • โœ“One-click SI โ‡„ Imperial toggle โ€” values convert in place, physics stays in SI
  • โœ“Live worked example: the substitution recomputes from your numbers
  • โœ“Built-in engineering verdict flags out-of-range results instantly
  • โœ“Runs entirely in your browser โ€” nothing uploaded, free forever

Frequently asked questions

What formula does the Dosing Pump Stroke Setting Calculator use?+

It computes stroke % = Q_required / Q_max ร— 100, per API 675 โ€” controlled volume pumps. The formula is displayed under the result along with a worked example substituted with your own inputs.

What should I keep in mind when using this calculator?+

Diaphragm metering pumps stay linear mid-range but drift at the extremes. Calibrate with a draw-down cylinder โ€” nameplate capacity assumes rated back-pressure.

Can I use this for pump selection?+

Use it to establish the duty (flow, head, NPSH, power) and then pick a pump whose curve passes through that point near best efficiency. The tool gives you the engineering numbers a supplier will ask for.

Is the Dosing Pump Stroke Setting Calculator free to use?+

Yes โ€” completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.