Gas Furnace Sizing Calculator

Input & output BTU for a furnace from the design heat loss and AFUE efficiency.

0
Required output (kW)
0
Furnace input rating (kW)

Furnaces are sold by INPUT BTU. A 100k input @ 95 AFUE delivers 95k. Chronic oversizing = short cycles, cold drafts, cracked heat exchangers.

Formula

Output = loss ร— (1+margin); Input = Output / AFUE
References: ACCA Manual J/S

Gas Furnace Sizing Calculator is a free furnace size for HVAC designers, technicians and energy auditors โ€” instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Gas Furnace Sizing Calculator

Input & output BTU for a furnace from the design heat loss and AFUE efficiency. The calculation implements Output = loss ร— (1+margin); Input = Output / AFUE (ACCA Manual J/S). Furnaces are sold by INPUT BTU. A 100k input @ 95 AFUE delivers 95k. Chronic oversizing = short cycles, cold drafts, cracked heat exchangers.

How to use Gas Furnace Sizing Calculator

  1. 1Enter Design heat loss in kW (From a heat-loss calc or ~40โ€“60 BTU/ftยฒ cold climate).
  2. 2Enter Furnace AFUE in %.
  3. 3Enter Sizing margin in % (ACCA allows up to 40% oversize max).
  4. 4Read Required output, Furnace input rating instantly โ€” no submit button needed.
  5. 5Need US units? Flip the SI/Imperial toggle and every field converts.

Why use Gas Furnace Sizing Calculator?

  • โœ“Implements the standard formula โ€” Output = loss ร— (1+margin); Input = Output / AFUE
  • โœ“Reference cited on-page: ACCA Manual J/S
  • โœ“One-click SI โ‡„ Imperial toggle โ€” values convert in place, physics stays in SI
  • โœ“Runs entirely in your browser โ€” nothing uploaded, free forever

Frequently asked questions

What formula does the Gas Furnace Sizing Calculator use?+

It computes Output = loss ร— (1+margin); Input = Output / AFUE, per ACCA Manual J/S. The formula is displayed under the result.

What should I keep in mind when using this calculator?+

Furnaces are sold by INPUT BTU. A 100k input @ 95 AFUE delivers 95k. Chronic oversizing = short cycles, cold drafts, cracked heat exchangers.

Is this based on ASHRAE methods?+

The calculations follow the standard ASHRAE/ISHRAE formulations cited under the result, simplified where industry practice does the same. For permit-grade design, confirm with the full code procedure.

Is the Gas Furnace Sizing Calculator free to use?+

Yes โ€” completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.