ToolJoltTools

Paint DFT Calculator (WFT × Solids)

Dry film from wet film and volume solids — the coating inspector's triangle.

0
Dry film thickness (µm)

The wet-film comb tells you NOW (fixable); the dry gauge tells you too late. Painters chase WFT = target DFT ÷ solids — 200 µm wet of a 65% epoxy leaves 124 µm dry.

Formula

DFT = WFT × VS% / (1 + thinner%)
References: SSPC-PA 2; coating inspector practice

Paint DFT Calculator (WFT × Solids) is a free dft calculator for design engineers, metallurgists and QA inspectors — instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Paint DFT Calculator (WFT × Solids)

Dry film from wet film and volume solids — the coating inspector's triangle. The calculation implements DFT = WFT × VS% / (1 + thinner%) (SSPC-PA 2; coating inspector practice). The wet-film comb tells you NOW (fixable); the dry gauge tells you too late. Painters chase WFT = target DFT ÷ solids — 200 µm wet of a 65% epoxy leaves 124 µm dry.

How to use Paint DFT Calculator (WFT × Solids)

  1. 1Enter Wet film thickness in µm.
  2. 2Enter Volume solids in % (Epoxy HB 65–80 · alkyd 45–55 · inorganic zinc ~60).
  3. 3Enter Thinner added in %.
  4. 4Read Dry film thickness instantly — no submit button needed.

Why use Paint DFT Calculator (WFT × Solids)?

  • Implements the standard formula — DFT = WFT × VS% / (1 + thinner%)
  • Reference cited on-page: SSPC-PA 2; coating inspector practice
  • Live worked example: the substitution recomputes from your numbers
  • Runs entirely in your browser — nothing uploaded, free forever

Frequently asked questions

What formula does the Paint DFT Calculator (WFT × Solids) use?+

It computes DFT = WFT × VS% / (1 + thinner%), per SSPC-PA 2; coating inspector practice. The formula is displayed under the result along with a worked example substituted with your own inputs.

What should I keep in mind when using this calculator?+

The wet-film comb tells you NOW (fixable); the dry gauge tells you too late. Painters chase WFT = target DFT ÷ solids — 200 µm wet of a 65% epoxy leaves 124 µm dry.

Where do the material property defaults come from?+

Defaults are standard handbook values (ASM, manufacturer datasheets, the cited standard). Always substitute certified values from your material's test certificate for critical work.

Is the Paint DFT Calculator (WFT × Solids) free to use?+

Yes — completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.