ToolJoltTools

Pump Head from Gauge Readings

Actual developed head from suction & discharge gauges, including gauge elevation offset.

0
Developed head (m)

Forgetting the gauge-height correction is the classic field-test error. Read both gauges at the same instant โ€” system transients lie.

Formula

H = (P_d โˆ’ P_s)/ฯg + ฮ”z_gauges (+ velocity-head difference if bores differ)
References: ANSI/HI 14.6 โ€” field acceptance tests

Pump Head from Gauge Readings is a free pump head measurement for pump engineers, plumbers and plant designers โ€” instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Pump Head from Gauge Readings

Actual developed head from suction & discharge gauges, including gauge elevation offset. The calculation implements H = (P_d โˆ’ P_s)/ฯg + ฮ”z_gauges (+ velocity-head difference if bores differ) (ANSI/HI 14.6 โ€” field acceptance tests). Forgetting the gauge-height correction is the classic field-test error. Read both gauges at the same instant โ€” system transients lie.

How to use Pump Head from Gauge Readings

  1. 1Enter Suction gauge in kPa(g) (Negative if under vacuum).
  2. 2Enter Discharge gauge in kPa(g).
  3. 3Enter Discharge gauge height above suction gauge in m.
  4. 4Enter Liquid SG.
  5. 5Read Developed head instantly โ€” no submit button needed.
  6. 6Need US units? Flip the SI/Imperial toggle and every field converts.

Why use Pump Head from Gauge Readings?

  • โœ“Implements the standard formula โ€” H = (P_d โˆ’ P_s)/ฯg + ฮ”z_gauges (+ velocity-head difference if bores differ)
  • โœ“Reference cited on-page: ANSI/HI 14.6 โ€” field acceptance tests
  • โœ“One-click SI โ‡„ Imperial toggle โ€” values convert in place, physics stays in SI
  • โœ“Live worked example: the substitution recomputes from your numbers
  • โœ“Runs entirely in your browser โ€” nothing uploaded, free forever

Frequently asked questions

What formula does the Pump Head from Gauge Readings use?+

It computes H = (P_d โˆ’ P_s)/ฯg + ฮ”z_gauges (+ velocity-head difference if bores differ), per ANSI/HI 14.6 โ€” field acceptance tests. The formula is displayed under the result along with a worked example substituted with your own inputs.

What should I keep in mind when using this calculator?+

Forgetting the gauge-height correction is the classic field-test error. Read both gauges at the same instant โ€” system transients lie.

Can I use this for pump selection?+

Use it to establish the duty (flow, head, NPSH, power) and then pick a pump whose curve passes through that point near best efficiency. The tool gives you the engineering numbers a supplier will ask for.

Is the Pump Head from Gauge Readings free to use?+

Yes โ€” completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.