ToolJoltTools

3-Phase Distro Balance Calculator

Balance a lighting rig across three phases: enter total load and see per-phase current and the imbalance to even out.

Balanced current per phase (A)
โ€”
Worst-phase current (A)
โ€”

An 18 kW rig should pull ~26 A on each of three phases when balanced. Pile too much on one phase and that leg's breaker trips while the others idle โ€” and an unbalanced neutral can overheat. Spread fixtures across phases as you patch so the distro sits near the even figure.

Rule / Formula

balanced per-phase current = total W รท 3 รท phase voltage; worst phase = total ร— share รท voltage
References: Three-phase power distribution; touring electrics practice

Note: Planning aid only โ€” phase distribution and neutral loading must be verified by a qualified electrician.

Balance a lighting rig across three phases: enter total load and see per-phase current and the imbalance to even out.

About 3-Phase Distro Balance Calculator

Balance a lighting rig across three phases: enter total load and see per-phase current and the imbalance to even out. An 18 kW rig should pull ~26 A on each of three phases when balanced. Pile too much on one phase and that leg's breaker trips while the others idle โ€” and an unbalanced neutral can overheat. Spread fixtures across phases as you patch so the distro sits near the even figure.

How to use 3-Phase Distro Balance Calculator

  1. 1Enter your values into the fields in 3-Phase Distro Balance Calculator.
  2. 2The result and any pass/fail verdict update instantly as you type โ€” no button to press.
  3. 3Check the substituted formula and worked example to see exactly how the result was derived.
  4. 4Copy or note the result for your spec, delivery or planning.

Why use 3-Phase Distro Balance Calculator?

  • โœ“Runs entirely in your browser with instant, private results โ€” no data leaves your device.
  • โœ“Built on a published reference: Three-phase power distribution; touring electrics practice.
  • โœ“Shows the governing formula and a worked example, so you can trust and check every result.
  • โœ“100% free with no sign-up, no watermark and no usage limits.
  • โœ“Works on any device โ€” desktop, tablet or phone โ€” and keeps working offline once loaded.

Frequently asked questions

What does 3-Phase Distro Balance Calculator do?+

Balance a lighting rig across three phases: enter total load and see per-phase current and the imbalance to even out. An 18 kW rig should pull ~26 A on each of three phases when balanced.

Is my data private?+

Yes. 3-Phase Distro Balance Calculator runs entirely in your browser โ€” your inputs are never uploaded, stored or logged.

What standard or source is 3-Phase Distro Balance Calculator based on?+

It follows Three-phase power distribution; touring electrics practice. Always confirm against the current official document, as specifications and rates can change.

What formula does it use?+

3-Phase Distro Balance Calculator uses: balanced per-phase current = total W รท 3 รท phase voltage; worst phase = total ร— share รท voltage. The tool shows this formula with your own numbers substituted so you can verify the result.

Is 3-Phase Distro Balance Calculator free to use?+

Yes โ€” it is completely free with no account, no sign-up and no usage limits. There is no watermark and no paywall.

Embed 3-Phase Distro Balance Calculator on your website

Want 3-Phase Distro Balance Calculatoron your own site? Paste this snippet into any HTML page โ€” it's free, with no API key or sign-up. The tool loads in an iframe and keeps working exactly as it does here.

Embed code
<iframe src="https://tooljolt.com/tools/three-phase-distro-balance-calculator" width="100%" height="640" style="border:1px solid #e5e7eb;border-radius:12px;max-width:680px" title="3-Phase Distro Balance Calculator โ€” ToolJolt" loading="lazy"></iframe>

Related tools

Related Broadcast tools

Sponsored