ToolJoltTools

Vibration Isolation Calculator

Transmissibility and isolation % from frequency ratio.

0
Frequency ratio r
0
Transmissibility
0
Isolation (%)

Below √2× the mount frequency, isolators make things WORSE — the most common AV-mount installation error. More damping helps at resonance but hurts isolation above it.

Formula

T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)], r = f/f_n
References: Den Hartog; mount manufacturer charts

Vibration Isolation Calculator is a free vibration isolation for mechanical and machine-design engineers — instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Vibration Isolation Calculator

Transmissibility and isolation % from frequency ratio. The calculation implements T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)], r = f/f_n (Den Hartog; mount manufacturer charts). Below √2× the mount frequency, isolators make things WORSE — the most common AV-mount installation error. More damping helps at resonance but hurts isolation above it.

How to use Vibration Isolation Calculator

  1. 1Enter Disturbing frequency in Hz (1,500 rpm = 25 Hz).
  2. 2Enter Mount natural frequency in Hz.
  3. 3Enter Damping ratio (Rubber 0.05 · springs 0.005).
  4. 4Read Frequency ratio r, Transmissibility, Isolation instantly — no submit button needed.

Why use Vibration Isolation Calculator?

  • Implements the standard formula — T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)], r = f/f_n
  • Reference cited on-page: Den Hartog; mount manufacturer charts
  • Built-in engineering verdict flags out-of-range results instantly
  • Runs entirely in your browser — nothing uploaded, free forever

Frequently asked questions

What formula does the Vibration Isolation Calculator use?+

It computes T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)], r = f/f_n, per Den Hartog; mount manufacturer charts. The formula is displayed under the result.

What should I keep in mind when using this calculator?+

Below √2× the mount frequency, isolators make things WORSE — the most common AV-mount installation error. More damping helps at resonance but hurts isolation above it.

Is this suitable for machine design coursework?+

Yes — these are the exact Shigley/Machinery's-Handbook formulas, with the substitution shown step by step, so you can follow the worked example into your own calculation sheet.

Is the Vibration Isolation Calculator free to use?+

Yes — completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.

Related tools

Related Engineering tools

Sponsored