ToolJoltTools

Welder Duty Cycle Checker

Can your machine hold this current? Duty-cycle math in both directions.

0
Available duty at your current (%)
0
Arc minutes per 10-min cycle (min)

Duty cycle scales with current SQUARED โ€” drop 20% in amps and a 60% machine becomes near-continuous. Ratings assume 40 ยฐC ambient; a summer tin shed derates further.

Formula

Dโ‚‚ = Dโ‚ยท(Iโ‚/Iโ‚‚)ยฒ
References: IEC 60974-1 duty cycle definition

Welder Duty Cycle Checker is a free duty cycle welding for welding engineers, fabricators and CWI inspectors โ€” instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Welder Duty Cycle Checker

Can your machine hold this current? Duty-cycle math in both directions. The calculation implements Dโ‚‚ = Dโ‚ยท(Iโ‚/Iโ‚‚)ยฒ (IEC 60974-1 duty cycle definition). Duty cycle scales with current SQUARED โ€” drop 20% in amps and a 60% machine becomes near-continuous. Ratings assume 40 ยฐC ambient; a summer tin shed derates further.

How to use Welder Duty Cycle Checker

  1. 1Enter Machine rated current in A.
  2. 2Enter Rated duty cycle in % (At 40 ยฐC, per 10-min cycle).
  3. 3Enter Current you'll weld at in A.
  4. 4Read Available duty at your current, Arc minutes per 10-min cycle instantly โ€” no submit button needed.

Why use Welder Duty Cycle Checker?

  • โœ“Implements the standard formula โ€” Dโ‚‚ = Dโ‚ยท(Iโ‚/Iโ‚‚)ยฒ
  • โœ“Reference cited on-page: IEC 60974-1 duty cycle definition
  • โœ“Live worked example: the substitution recomputes from your numbers
  • โœ“Runs entirely in your browser โ€” nothing uploaded, free forever

Frequently asked questions

What formula does the Welder Duty Cycle Checker use?+

It computes Dโ‚‚ = Dโ‚ยท(Iโ‚/Iโ‚‚)ยฒ, per IEC 60974-1 duty cycle definition. The formula is displayed under the result along with a worked example substituted with your own inputs.

What should I keep in mind when using this calculator?+

Duty cycle scales with current SQUARED โ€” drop 20% in amps and a 60% machine becomes near-continuous. Ratings assume 40 ยฐC ambient; a summer tin shed derates further.

Does this follow AWS/IS welding codes?+

Each tool implements the formula from the cited code or handbook (AWS D1.1, IS 800, ISO/EN). Qualified WPS values always govern over any calculator for code work.

Is the Welder Duty Cycle Checker free to use?+

Yes โ€” completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.