ToolJoltTools

Paint Booth CFM Calculator

Cross-draft booth airflow from face area at the 100 fpm capture velocity.

0
Exhaust airflow (L/s)
0
Airflow (mยณ/h)

Filters loading with overspray drop the face velocity day by day โ€” a manometer across the filter bank tells you when capture is failing.

Formula

Q = face area ร— capture velocity
References: OSHA 1910.94(c); NFPA 33

Paint Booth CFM Calculator is a free paint booth cfm for HVAC designers, technicians and energy auditors โ€” instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Paint Booth CFM Calculator

Cross-draft booth airflow from face area at the 100 fpm capture velocity. The calculation implements Q = face area ร— capture velocity (OSHA 1910.94(c); NFPA 33). Filters loading with overspray drop the face velocity day by day โ€” a manometer across the filter bank tells you when capture is failing.

How to use Paint Booth CFM Calculator

  1. 1Enter Booth opening width in m.
  2. 2Enter Booth opening height in m.
  3. 3Enter Face velocity in m/s (OSHA/NFPA cross-draft: 100 fpm (0.5 m/s)).
  4. 4Read Exhaust airflow, Airflow instantly โ€” no submit button needed.
  5. 5Need US units? Flip the SI/Imperial toggle and every field converts.

Why use Paint Booth CFM Calculator?

  • โœ“Implements the standard formula โ€” Q = face area ร— capture velocity
  • โœ“Reference cited on-page: OSHA 1910.94(c); NFPA 33
  • โœ“One-click SI โ‡„ Imperial toggle โ€” values convert in place, physics stays in SI
  • โœ“Live worked example: the substitution recomputes from your numbers
  • โœ“Runs entirely in your browser โ€” nothing uploaded, free forever

Frequently asked questions

What formula does the Paint Booth CFM Calculator use?+

It computes Q = face area ร— capture velocity, per OSHA 1910.94(c); NFPA 33. The formula is displayed under the result along with a worked example substituted with your own inputs.

What should I keep in mind when using this calculator?+

Filters loading with overspray drop the face velocity day by day โ€” a manometer across the filter bank tells you when capture is failing.

Is this based on ASHRAE methods?+

The calculations follow the standard ASHRAE/ISHRAE formulations cited under the result, simplified where industry practice does the same. For permit-grade design, confirm with the full code procedure.

Is the Paint Booth CFM Calculator free to use?+

Yes โ€” completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.