Bathroom Exhaust Fan Size Calculator
HVI-method fan size from floor area and fixtures, with duct-length reality check.
Rated CFM assumes 0.1 in wg โ a long flex run can halve it. Buy the 0.25 in wg rating if the duct exceeds ~5 m, and vent OUTSIDE, never into the attic.
Formula
Bathroom Exhaust Fan Size Calculator is a free bathroom fan size for HVAC designers, technicians and energy auditors โ instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.
About Bathroom Exhaust Fan Size Calculator
HVI-method fan size from floor area and fixtures, with duct-length reality check. The calculation implements Small rooms: 1 CFM/ftยฒ (min 50); large rooms: 50 CFM per fixture (HVI 2016 ventilation guidelines; IRC M1505). Rated CFM assumes 0.1 in wg โ a long flex run can halve it. Buy the 0.25 in wg rating if the duct exceeds ~5 m, and vent OUTSIDE, never into the attic.
How to use Bathroom Exhaust Fan Size Calculator
- 1Enter Bathroom area in mยฒ.
- 2Enter Fixtures (toilet+shower+tub counts).
- 3Enter Larger than 9.3 mยฒ (100 ftยฒ)? (1 = yes โ fixture method).
- 4Read Required fan instantly โ no submit button needed.
- 5Need US units? Flip the SI/Imperial toggle and every field converts.
Why use Bathroom Exhaust Fan Size Calculator?
- โImplements the standard formula โ Small rooms: 1 CFM/ftยฒ (min 50); large rooms: 50 CFM per fixture
- โReference cited on-page: HVI 2016 ventilation guidelines; IRC M1505
- โOne-click SI โ Imperial toggle โ values convert in place, physics stays in SI
- โRuns entirely in your browser โ nothing uploaded, free forever
Frequently asked questions
What formula does the Bathroom Exhaust Fan Size Calculator use?+
It computes Small rooms: 1 CFM/ftยฒ (min 50); large rooms: 50 CFM per fixture, per HVI 2016 ventilation guidelines; IRC M1505. The formula is displayed under the result.
What should I keep in mind when using this calculator?+
Rated CFM assumes 0.1 in wg โ a long flex run can halve it. Buy the 0.25 in wg rating if the duct exceeds ~5 m, and vent OUTSIDE, never into the attic.
Is this based on ASHRAE methods?+
The calculations follow the standard ASHRAE/ISHRAE formulations cited under the result, simplified where industry practice does the same. For permit-grade design, confirm with the full code procedure.
Is the Bathroom Exhaust Fan Size Calculator free to use?+
Yes โ completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.
Related Engineering tools
Reynolds Number Calculator
Compute Re from density, velocity, pipe diameter and viscosity โ with instant laminar/turbulent classification.
โ LiveLaminar vs Turbulent Flow Classifier
Classify hydraulic-oil or process-fluid flow regime from kinematic viscosity, line velocity and tube bore.
โ LiveBernoulli Equation Solver
Solve downstream pressure between two points from velocities, elevations and fluid density (ideal, lossless).
โ Live