Makeup Air Calculator

Makeup air a big range hood or exhaust fan demands before it depressurizes the house.

0
Makeup air required (L/s)

Backdrafting a water heater or fireplace is the real hazard โ€” a 900 CFM hood in a tight house WILL pull flue gases backwards without MUA.

Formula

MUA = ฮฃ exhaust โˆ’ infiltration credit (IRC trigger: hoods > 400 CFM)
References: IRC M1503.6 โ€” makeup air for range hoods

Makeup Air Calculator is a free makeup air for HVAC designers, technicians and energy auditors โ€” instant, accurate and 100% client-side, with the governing formula and reference shown next to the result so the number can be defended, not just quoted.

About Makeup Air Calculator

Makeup air a big range hood or exhaust fan demands before it depressurizes the house. The calculation implements MUA = ฮฃ exhaust โˆ’ infiltration credit (IRC trigger: hoods > 400 CFM) (IRC M1503.6 โ€” makeup air for range hoods). Backdrafting a water heater or fireplace is the real hazard โ€” a 900 CFM hood in a tight house WILL pull flue gases backwards without MUA.

How to use Makeup Air Calculator

  1. 1Enter Largest exhaust device in L/s.
  2. 2Enter Other simultaneous exhaust in L/s.
  3. 3Enter House leakage credit in L/s (Tight new homes: very little).
  4. 4Read Makeup air required instantly โ€” no submit button needed.
  5. 5Need US units? Flip the SI/Imperial toggle and every field converts.

Why use Makeup Air Calculator?

  • โœ“Implements the standard formula โ€” MUA = ฮฃ exhaust โˆ’ infiltration credit (IRC trigger: hoods > 400 CFM)
  • โœ“Reference cited on-page: IRC M1503.6 โ€” makeup air for range hoods
  • โœ“One-click SI โ‡„ Imperial toggle โ€” values convert in place, physics stays in SI
  • โœ“Runs entirely in your browser โ€” nothing uploaded, free forever

Frequently asked questions

What formula does the Makeup Air Calculator use?+

It computes MUA = ฮฃ exhaust โˆ’ infiltration credit (IRC trigger: hoods > 400 CFM), per IRC M1503.6 โ€” makeup air for range hoods. The formula is displayed under the result.

What should I keep in mind when using this calculator?+

Backdrafting a water heater or fireplace is the real hazard โ€” a 900 CFM hood in a tight house WILL pull flue gases backwards without MUA.

Is this based on ASHRAE methods?+

The calculations follow the standard ASHRAE/ISHRAE formulations cited under the result, simplified where industry practice does the same. For permit-grade design, confirm with the full code procedure.

Is the Makeup Air Calculator free to use?+

Yes โ€” completely free, no sign-up, no limits. It runs client-side in your browser, so inputs stay private and results are instant even on slow connections.